Flame Proof Toxic Gas Detector Specification

  • Operate Method
  • Semi Automatic
  • Resistance
  • 250 Ohm
  • Usage
  • Commercial
  • Material
  • Stainless Steel
  • Output
  • Digital Sensor
  • Theory
  • Electrochemical / Semiconductor Sensing
  • Type
  • Flame Proof Toxic Gas Detector
  • Accuracy
  • 3% FSD
  • Operating Voltage
  • 18~30V DC
  • Output Voltage
  • 4-20 mA Analog / Digital Output
  • Compensated Temperature
  • -10C to +55C
  • Storage Temperature
  • -20C to +60C
  • Operating Temperature
  • -10C to +55C
  • Ingress Protection
  • IP66 / Weatherproof
  • Sensor Life
  • 2 years typical
  • Response Time
  • <30 seconds
  • Display
  • LED / LCD (Optional)
  • Mounting
  • Wall Mounted
  • Dimensions
  • Approx. 180mm x 120mm x 90mm
  • Alarm
  • Visual & Audible (Optional)
  • Weight
  • Approx. 2 kg
  • Gas Detected
  • Toxic Gases such as CO, H2S, NH3, Cl2, SO2 (model specific)
 

Flame Proof Toxic Gas Detector Trade Information

  • Minimum Order Quantity
  • 50 Pieces
  • Payment Terms
  • Cash Advance (CA)
  • Supply Ability
  • 5000 Pieces Per Month
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

About Flame Proof Toxic Gas Detector

As a notable firm, we are dealing with manufacturing and providing In Flame Proof Toxic Gas Detector to our client. It is best choice to use in chemical plants and manufacturing facilities for detecting the gas by monitoring potential leakage areas for harmful gas levels. This item is made by using high quality required materials with the help of latest technology under the visionary of our experts. Flame Proof Toxic Gas Detector is demanded in the market because of its good quality and excellent performance. All the provided items are tested on the various quality parameters before final dispatch. We offer the same at market leading price rate.



Robust and Weatherproof Design

Crafted from stainless steel and meeting IP66 ingress protection standards, this flame proof detector guarantees reliable operation in harsh industrial or commercial settings. Its weatherproof capabilities and sturdy construction ensure durability and minimal maintenance even in challenging conditions.


Advanced Sensing and Fast Response

Leveraging electrochemical or semiconductor technology, this detector identifies toxic gases swiftly-delivering a response in under 30 seconds. High accuracy combined with rapid detection supports enhanced workplace safety and timely hazard mitigation.


Flexible Output and Alarm Features

With digital and analog (4-20 mA) outputs, and optional visual and audible alarms, the detector integrates easily into existing safety systems. The optional LED/LCD display provides immediate status updates, facilitating efficient environmental monitoring.

FAQ's of Flame Proof Toxic Gas Detector:


Q: How does the Flame Proof Toxic Gas Detector identify hazardous gases?

A: The detector employs advanced electrochemical or semiconductor sensors, which react specifically to target gases such as CO, H2S, NH3, Cl2, or SO2. This technology ensures accurate measurements and quick responses to changing gas concentrations in the environment.

Q: What is the recommended installation process for this toxic gas detector?

A: The device is designed for wall mounting in commercial or industrial spaces where toxic gas risks exist. Follow the manufacturer's guidelines for positioning, ensuring adequate airflow to the sensor for optimal performance and safety compliance.

Q: Where is this gas detector ideally used?

A: This flame proof toxic gas detector is suited for commercial and industrial environments, such as chemical processing plants, refineries, and manufacturing units where hazardous gas leaks could jeopardize safety.

Q: When is sensor replacement necessary?

A: Typically, the sensor has a lifespan of about 2 years under normal operating conditions. It's recommended to replace the sensor at the end of its expected life or if calibration tests indicate reduced sensitivity.

Q: What are the benefits of using this gas detector in a facility?

A: Employing this detector improves workplace safety by providing early warnings against toxic gas exposures. It helps organizations comply with regulatory safety standards, thus protecting personnel and assets.

Q: How is information from the detector communicated to safety systems?

A: The detector features both analog (4-20 mA) and digital output options, allowing seamless integration with existing control systems. Optional visual and audible alarms further enhance on-site awareness and response capabilities.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Continuous Gas Detection System Category

Oxygen Gas Detector

Oxygen Gas Detector

Minimum Order Quantity : 50 Pieces

Usage : Commercial

Theory : Other, Electrochemical Sensor

Accuracy : 3% F.S.

Material : Stainless Steel

Storage Temperature : 40C to +70C

WD 600 Two Channel Digital Gas Monitor Controller Unit

WD 600 Two Channel Digital Gas Monitor Controller Unit

Minimum Order Quantity : 50 Pieces

Usage : Commercial

Theory : Other, Gas Sensing and Monitoring

Accuracy : 3% FS

Material : Stainless Steel

Storage Temperature : 20C to 60C

Multi Channel Digital Gas Monitor Controller Unit

Multi Channel Digital Gas Monitor Controller Unit

Minimum Order Quantity : 50 Pieces

Usage : Commercial

Theory : Other, Gas Detection and Monitoring

Accuracy : 1% FS

Material : Stainless Steel

Storage Temperature : 20C to +60C

T 2011HMI Gas Monitor Control Panel

T 2011HMI Gas Monitor Control Panel

Minimum Order Quantity : 50 Pieces

Usage : Commercial

Theory : Other, Gas Detection

Accuracy : 3% F.S.

Material : Stainless Steel

Storage Temperature : 20C to 60C



WORLDWIDE SAFETY DEVICES
GST : 27ADHPT0792N1ZT