T 2011HMI Gas Monitor Control Panel Specification

  • Operate Method
  • Semi Automatic
  • Resistance
  • 100 M
  • Material
  • Stainless Steel
  • Usage
  • Commercial
  • Output
  • Digital Sensor
  • Theory
  • Gas Detection
  • Type
  • Wall Mount, HMI Control Panel
  • Accuracy
  • 3% F.S.
  • Operating Voltage
  • 220V AC 10%, 50Hz
  • Output Voltage
  • 24V DC
  • Compensated Temperature
  • -10C to 55C
  • Storage Temperature
  • -20C to 60C
  • Operating Temperature
  • 0C to 55C
 

T 2011HMI Gas Monitor Control Panel Trade Information

  • Minimum Order Quantity
  • 50 Pieces
  • Payment Terms
  • Cash Advance (CA)
  • Supply Ability
  • 5000 Pieces Per Month
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

About T 2011HMI Gas Monitor Control Panel

Considering our rich experience and knowledge, our firm is named amongst the leading manufacturers and providers of T 2011HMI Gas Monitor Control Panel to our clients. It is made by using unmatched quality materials and advanced techniques under the supervision of our professionals to match with the requirements of our prestigious clients. This panel is utilized in parking garages and other commercial, industrial, and residential facilities for maintaining the acceptable air quality. All the provided items are tested on the various quality parameters before final dispatch. We offer this Gas Monitor Control Panel at market leading price rate within the stipulated time period.



Advanced HMI Touchscreen Control

The T 2011HMI Gas Monitor Control Panel boasts a 7-inch TFT color HMI touchscreen, making it user-friendly and visually clear. Operators can quickly access status information, alarms, and settings, streamlining the monitoring process and troubleshooting. This human-machine interface enhances control efficiency in commercial environments.


Robust Channel and Integration Options

Capable of handling up to 8 independent channels, this panel supports multiple gas sensors for comprehensive coverage. The RS485 MODBUS communications interface enables effortless integration into existing building management or automation systems, ensuring seamless data exchange and control.


Durable Construction for Secure Operation

Constructed from stainless steel and rated at IP54, the T 2011HMI Control Panel ensures protection against dust and splashes. Its wall-mount design and compact dimensions make it suitable for diverse installation sites, while the reliable relay alarm outputs guarantee timely alerts and safety precautions.

FAQ's of T 2011HMI Gas Monitor Control Panel:


Q: How is the T 2011HMI Gas Monitor Control Panel installed and what are the mounting requirements?

A: The panel is designed for wall-mounted installation and measures 380mm x 300mm x 120mm. Its stainless steel enclosure is rated IP54, providing dependable protection in various commercial environments. Ensure the mounting site allows access to a 220V AC power supply for proper operation.

Q: What process does the control panel use to detect gas and generate alerts?

A: This system utilizes digital sensors connected to up to 8 channels. When a gas detection event is registered, the control panel quickly processes the signal, displaying the data on the HMI screen and activating relay outputs for alarms. The response time is typically less than 30 seconds, ensuring swift protective measures.

Q: Where can this Gas Monitor Control Panel be effectively used?

A: The control panel is primarily intended for commercial applications such as factories, warehouses, laboratories, or other locations where gas monitoring is essential. Its robust construction and reliable operation make it suitable for indoor environments exposed to industrial conditions.

Q: What is the benefit of having RS485 MODBUS communication on the panel?

A: RS485 MODBUS communication allows the control panel to interface with other automation or supervisory control systems. This feature enhances integration, visibility, and remote management of gas detection, contributing to improved safety and operational efficiency.

Q: When should periodic maintenance or calibration be performed on the gas sensors?

A: Regular sensor calibration and maintenance are recommended to maintain measurement accuracy, targeted at intervals suggested by the sensor manufacturer or based on environmental conditions. Periodic checks help ensure the system's reliability and prolong its service life.

Q: How does the panel's alarm system help protect users and property?

A: Upon detecting unsafe gas levels, the control panel triggers relay alarms (NO/NC contacts) to alert personnel and activate safety measures such as exhaust fans or emergency shutdowns. This rapid response enhances protection and helps minimize risk to both humans and assets.

Q: What are the operating and storage temperature ranges for the panel?

A: The panel can operate effectively in temperatures from 0C to 55C and be safely stored in environments from -20C to 60C. It is also temperature compensated for stable performance between -10C and 55C.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Continuous Gas Detection System Category

WD 600 Two Channel Digital Gas Monitor Controller Unit

WD 600 Two Channel Digital Gas Monitor Controller Unit

Minimum Order Quantity : 50 Pieces

Storage Temperature : 20C to 60C

Operating Voltage : AC 220V

Material : Stainless Steel

Resistance : Up to 250

Output : Digital Sensor

WSD1 2  Flame Proof HC Gas Detector

WSD1 2 Flame Proof HC Gas Detector

Minimum Order Quantity : 50 Pieces

Storage Temperature : 40C to +85C

Operating Voltage : 1836V DC

Material : Stainless Steel

Resistance : 500

Output : Digital Sensor

Multi Channel Digital Gas Monitor Controller Unit

Multi Channel Digital Gas Monitor Controller Unit

Minimum Order Quantity : 50 Pieces

Storage Temperature : 20C to +60C

Operating Voltage : 230V AC, 50Hz

Material : Stainless Steel

Resistance : <300 Ohms

Output : Digital Sensor

Flame Proof Toxic Gas Detector

Flame Proof Toxic Gas Detector

Minimum Order Quantity : 50 Pieces

Storage Temperature : 20C to +60C

Operating Voltage : 18~30V DC

Material : Stainless Steel

Resistance : 250 Ohm

Output : Digital Sensor



WORLDWIDE SAFETY DEVICES
GST : 27ADHPT0792N1ZT